Discover · spiceworks.com

No picture published by spiceworks.com

Sync UIDnumber for each site DC

Spiceworks Community spiceworks.com

This is what was read here when it was published. @jeremy-c6121 jeremy-c6121 no longer carries it in what it publishes now.

On the 2012 R2 tab question: the UNIX Attributes tab doesn’t scan users and isn’t tied to the RID Master (that role only hands out RID pools for SIDs). It reads a counter, msSFU30MaxUidNumber, stored on the NIS domain object at CN=YOURNISDOMAIN,CN=ypservers,CN=ypServ30,CN=RpcServices,CN=System,DC=yourdomain,DC=com, fills in that value and then bumps the counter. It does that on whichever DC your ADUC is connected to, so it has the same replication gap as your script: two people on DCs that haven’t caught up yet can get the same number.

If you want your script and the tab to agree, have the script use that same counter: read msSFU30MaxUidNumber on the PDC, assign it, then write it back plus one on the PDC. msSFU30MaxGidNumber sits next to it for groups.

More ways to use this

Open on another device

Scan this QR code to open the same public page

Scan to open this page. Your saved notes and account access are not included.

Download QR code

Open the page link

Keep going

Each of these is read from what this estate already kept: the feed a piece came through, the publisher behind it, the credits and topics the publisher printed. None of it is a recommendation, an identity or a record kept anywhere else.

Also from Spiceworks Community

  1. SpiceRex: Sand Art@asfasty asfasty spiceworks.com
  2. 1Password has a breach via Github. Vaults allegedly safe@sarahreid sarahreid spiceworks.com
  3. What are you thankful for?@Jay-Jay-01 Jay-Jay-01 spiceworks.com
  4. BE5000 Wi-Fi 7 access point for a small office — worth the jump from Wi-Fi 6?@molan molan spiceworks.com
  5. What 3d printer?@molan molan spiceworks.com
  6. Microsoft account won't log into Windows 11 or link to a local account@alexfogerty Alex Fogerty spiceworks.com